Description
2190 is the latest high-end ultrasonic thickness gauge that adopts pulse refection principle.It means the transducer sends ultrasonic pulses to travel through the test object and receives the reflection pulse from the backwall of the object. 2190 can nondestructively monitor the thickness of almost any material like metals, plastics, composites, fiberglass, ceramics, and glass with A scan/B scan. It is used to test the wall thickness and corrosion of various kinds of plates, pipes, boilers, vessels across industries like metallurgy, shipbuilding, machinery, chemical, aerospace, power, automotive, oil and gas, manufacturing and others.
- A-scan waveform can be displayed for echo analysis and measurement of complex workpiece;
- Compatible with many types of transducers, both single and dual element transducers;
- Users can set blanks to shield aftershocks or clutter;
- Echo-echo measures the true metal thickness with ignoring the thickness of coating layer.
- Thru-coat technology measures metal and nonmetallic coating thickness.
- Signal auto-amplification function (centered display of the detected echo);
- Adjustable voltage variable pulse width square wave pulse generator;
- Single value B-scan display function;
- Users can turn on fast measurement mode up to 20 times per second;
- Alarm function allows users to set the upper and lower limits of the alarm;
- Differential, maximum and minimum display mode;
- Store up to 500,000 measured values and waveforms.
Measuring range |
0.20~500mm |
Display resolution |
0.001 mm, 0.01 mm or 0.1 mm |
Sound velocity range |
508 m/s~18699m/s |
Repeatability |
5M probe and above: 0.03mm |
Display screen |
Color TFT LCD, 320x240 pixels |
Gain range |
0-99dB, 1dB step |
Pulse Generator |
Adjustable Square Wave Pulse Generator |
Emission voltage |
60V, 110V, 150V, 200V optional |
Emission pulse width |
varies with transducer frequency |
Frequency range |
0.5 Mhz~20Mhz |
Measurement rate |
standard (4Hz), fast (20Hz) |
Transducer settings |
10 sets of fixed setting and 22 sets of custom setting |
Data Storage |
500 data files, each capable of storing 1000 measurements and waveforms |
Interface |
USB |
Power |
three AA battery or NiMH batteries |
Working temperature |
0~40℃ |
Weight (g) |
360g |
Dimension |
187mm×87 mm×43 mm |
Transducer Measurement Range
Standard Delivery | Optional Accessory | |
Main unit | 1 | Communication cable |
5MHz dual crystal probe | 1 | Standard test block |
Couplant | 1 | Probes |
AA battery | 3 | |
TIME certificate | 1 | |
Warranty card | 1 | |
Instruction manual | 1 |
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.