Description
Features
- Investigation depth could reach 180mm
- Single comprehensive probe. No need to replace during test.
- Back-lit screen let instrumentcan be normal used under the condition of insufficient light
- Machine software is complete.The report could be printed automatically connecting with computer
- Grid scan of the rebar position
- Profile scan of the rebar position
Work Environment Condition
No strong alternating electromagnetic field
No corrosive gas in the air.
Avoid larger vibration and impact
Avoid the LCD panel contact with sunlight directly
Product Usage
Testing concrete cover thickness
Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution.
Estimation bar diameter
Detection of Cable and Plumbing pipe
Technical Specification
Bar diameter application range(mm) |
6-50
|
Maximum permissible error of Bar diameter |
≤±1
|
Cover thickness measuring range |
|
The first measuring range (mm) |
6-90 |
The second measuring range (mm) |
7-180 |
The maximum error of cover thickness |
||
The firstmeasuring range(mm) |
The second measuring range (mm) |
|
6-59
|
7-79
|
≤±1
|
60- 69
|
80 - 119
|
≤±2
|
70-90
|
120 - 180
|
≤±4
|
Accessory
Standard Delivery |
Optional Accessory |
Main unit, Software |
Scan car |
USB connecting cable |
Car cable |
Probe |
|
Probe cable |
|
Manual |
|
Warranty card |
|
Carry case |
Payment & Security